1、ApplicationBreaker pole position discordance can occur on the operation of a breaker with independent operating gears for the three poles.The reason may be an interruption in the closing or trip coil circuit,or a mechanical failure resulting in a stuck(卡住的,不能动的)breaker pole.A pole discordance can be

2、 tolerated for a limited time,for instance during a single-phase trip-reclose cycle.The pole discordance function detects a breaker pole discordancy not generated by auto-reclose cycle and issues a trip signal for the circuit breaker.1.Pole discordance protection(PD)FunctionalityThe operation of the

3、 pole discordance logic,PD,it based on checking the position of the breaker auxiliary contacts.Three parallel normally open contacts in series with three normally closed contacts in parallel of the respective breaker poles form a condition of pole discordance,connected to a binary dedicated for the

4、purpose.In addition,there is an automatic detection criterion based on comparison of currents in the breaker poles.This function is enabled for just a few seconds after close or trip commands to the breaker in order to avoid unwanted operation in unsymmetrical load conditions.1.Pole discordance prot

5、ection(PD)The PHS is an independent measuring function.It comprises both impedance and current-based measurement criteria.Its main purpose is to augment the phase selectivity of the complete distance protection in networks with long and heavily loaded lines.It is generally intended for use in direct

6、ly earthed networks,where correct and reliable phase selection for single-phase faults,combined with single-pole tripping and automatic reclosing,secures the stability of complete power systems.The independent measurement of impedance in all fault loops secures a high degree of phase selectivity in

7、complex networks.This independent phase selection,combined with directional measurement for each fault loop,also secures selective operation for simultaneous close-in faults on parallel circuits.Independent reactive reach settings for phase-to-phase and phase-to-earth measurement secures high selectivity in networks with different protective relays used for short-circuit and earth-fault protection.返回

展开阅读全文
相关资源
猜你喜欢
相关搜索
资源标签

当前位置:首页 > 办公、行业 > 各类PPT课件(模板)
版权提示 | 免责声明

1,本文(电气工程专业外教语学1课件.ppt)为本站会员(三亚风情)主动上传,163文库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。
2,用户下载本文档,所消耗的文币(积分)将全额增加到上传者的账号。
3, 若此文所含内容侵犯了您的版权或隐私,请立即通知163文库(发送邮件至3464097650@qq.com或直接QQ联系客服),我们立即给予删除!


侵权处理QQ:3464097650--上传资料QQ:3464097650

【声明】本站为“文档C2C交易模式”,即用户上传的文档直接卖给(下载)用户,本站只是网络空间服务平台,本站所有原创文档下载所得归上传人所有,如您发现上传作品侵犯了您的版权,请立刻联系我们并提供证据,我们将在3个工作日内予以改正。


163文库-Www.163Wenku.Com |网站地图|