SGT800-Product-presentat教学讲解课件.ppt

上传人(卖家):ziliao2023 文档编号:5962135 上传时间:2023-05-19 格式:PPT 页数:78 大小:10.08MB
下载 相关 举报
SGT800-Product-presentat教学讲解课件.ppt_第1页
第1页 / 共78页
SGT800-Product-presentat教学讲解课件.ppt_第2页
第2页 / 共78页
SGT800-Product-presentat教学讲解课件.ppt_第3页
第3页 / 共78页
SGT800-Product-presentat教学讲解课件.ppt_第4页
第4页 / 共78页
SGT800-Product-presentat教学讲解课件.ppt_第5页
第5页 / 共78页
点击查看更多>>
资源描述

1、E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 1SGT-800 Industrial gas turbinePower GenerationPlease address all correspondence to:Siemens Industrial Turbomachinery AB;SE-612 83 Finspong;Sweden Siemens Industrial Turbomachinery ABNo part of this document may be repr

2、oduced or transmitted in any form or by any means,including photocopying and recording without the written permission of Siemens Industrial Turbomachinery AB.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 2Contents Main features,benefits and experience Performance c

3、haracteristics Package design Core engine design Maintenance Reference sitesSGT-800 Industrial gas turbine.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 3Siemens range of Gas TurbinesSGT-800 47MWState-of-the-art and innovative gas turbinesto meet todays and tomorro

4、ws energy needs.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 4SGT-800 Industrial gas turbineSimple and robust for reliable power generation in the 47 MW-class.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 5SGT-800 Industrial gas

5、turbine Features and benefits High industrial gas turbine electrical efficiency Dual fuel low emissions technology Fuel changeover capability Stable load rejection capability,1,300,000 Lead Package hours 70,000 Fleet Availability98.2%*Fleet Reliability 99.8%*AF/RF figures based on a 12 month rolling

6、 average.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 8SGT-800 Industrial gas turbineInstallation locations1 turbine2 turbines3-4 turbines5-9 turbines10+turbines.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 9 World mapEurope1 tu

7、rbine2 turbines3 turbines5 turbines10 turbines.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 101 turbine2 turbines3 turbines5 turbines10 turbinesAfrica World map.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 111 turbine2 turbines3

8、 turbines5 turbines10 turbinesMiddle East World map.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 121 turbine2 turbines3 turbines5 turbines10 turbinesAsia World map.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 13Australia1 turbin

9、e2 turbines3 turbines5 turbines10 turbines World map.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 141 turbine2 turbines3 turbines5 turbines10 turbinesNorth America World map.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 151 turbi

10、ne2 turbines3 turbines5 turbines10 turbinesSouth America World map.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 16Contents Main features,benefits and experience Performance characteristics Package design Core engine design Maintenance Reference sitesSGT-800 Indust

11、rial gas turbine.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 17SGT-800 Industrial gas turbine Simple cycle performance-natural gasISO rating-base load Pe47 000 kW S.H.C.9 597 kJ/kWh /9096 Btu/kWh El.efficiency37.5%Exhaust mass flow131.5 kg/s /289.9 lb/s Exhaust t

12、emperature544 C /1,011 F.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 18SGT-800 Industrial gas turbine DLE combustion system capabilityEmission Guarantees are issued separately in each project,depending upon site conditions,required load range and other project sp

13、ecific data.Burner typeFuel50-100%loadNOx 15%O250-100%loadCO 15%O2NoteGas burnerNatural gas 15 ppmv 5 ppmvDryDual fuel burnerNatural gas 15 ppmv 5 ppmvDryDiesel No.2 42 ppmv 5 ppmvDry.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 19SGT-800 Industrial gas turbinePer

14、formanceFactors that affect power output include Inlet&exhaust system losses Humidity Fuel quality/type Temperature Altitude Atmospheric pressureSGT-800-47 Nominal Exhaust Mass Flow and temperature for gas fuel105110115120125130135140145150-40-30-20-10010203040Compressor Inlet Air Temperature,CExhau

15、st Mass Flow,kg/s510520530540550560570580590600Exhaust Temperature,CSGT-800-47 Nominal Generator Output and Heat Rate for gas fuel303540455055-40-30-20-10010203040Compressor Inlet Air Temperature,CGenerator Output,MW9.59.69.79.89.91010.110.210.310.410.5Heat Rate,MJ/kWh.E O IP Siemens Industrial Turb

16、omachinery AB 2011.All rights reserved.SGT-800Page 20100%fuel1-pressure HRSGGas Turbine11.2%losses51.6%process heat37.2%electricity Total Efficiency 88.8%SGT-800 Industrial gas turbineCogeneration cycle.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 21Steam Turbine(

17、condensing)100%fuel15 deg CGas Turbine2-pressure HRSG520 deg C27 deg C31 deg C31 deg C11.6%losses37.1%electricity17.2%electricity34.1%lossesSGT-800 Industrial gas turbineCombined cycle Total Efficiency 54.3%.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 22Steam Rai

18、sing Capabilities for Gas Turbine Co-Generation PlantNotes:1.Steam values are indicative only.Actual values depend on site configuration2.Firing to 850C only.Higher firing is available025507510012515017520005101520253035404550Power(MWe)Steam(tonnes/hr)12 bar saturatedUnfiredFiredSGT-100SGT-300SGT-40

19、0SGT-500SGT-600SGT-700SGT-800Fired steam raisingUnfired steam raisingSGT-200.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 23at ISO-conditions including lossesSGT-800 Industrial gas turbinePerformance-combined cycle,natural gasSCC-800 1x1Condensing operationNon-reh

20、eat,1 x SGT-800 GT46 000 kWeST21 400 kWeAuxiliaries -900 kWe Net total66 500 kWeFuel123 800 kJ/sEl.Efficiency53.7.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 24at ISO-conditions including lossesSGT-800 Industrial gas turbinePerformance-combined cycle,natural gasC

21、ondensing operationNon-reheat,2 x SGT-800 GT 92 100 kWeST 44 400 kWeAuxiliaries -1 400 kWe Net total 135 100 kWeFuel248 300 kJ/sEl.Efficiency54.4%SCC-800 2x1.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 25Part Load Performance Combined Cycle35404550556050607080901

22、00Base Load Power,%Efficiency,%SGT-800 Industrial gas turbineExcellent combined cycle part load efficiencyCondensing operationNon-reheat,1 x SGT-800 Natural gas fuel=LHV 46798 kJ/kg Altitude(sea level)=1,013 barRelative humidity=60%.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserve

23、d.SGT-800Page 26Contents Main features,benefits and experience Performance characteristics Package design Core engine design Maintenance Reference sitesSGT-800 Industrial gas turbine.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 27Combustion air inlet filterElectri

24、cal and Control moduleExhaustFire suppression cabinetEnclosure ventilation inletEnclosure ventilation outlet Lube oil coolerGenerator cooling air inletAC generatorGenerator air outletSGT-800 Industrial gas turbineGeneral Arrangement.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserve

25、d.SGT-800Page 28Small footprint Dimensions 27x7 m Auxiliary equipment on a separate skidStandardized The layout is basically the same for all applicationsSGT-800 Industrial gas turbineCompact and flexible layout.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 29 Lead

26、 time reduction Proven plant concept Maintainability improvement Long standing relations with key suppliers Risk reduction Availability increaseSGT-800 Standard reference plantCombined Cycle Power Plant.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 30Contents Main

27、features,benefits and experience Performance characteristics Package design Core engine design Maintenance Reference sitesSGT-800 Industrial gas turbine.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 311-shaft Gas TurbineSGT-800 Industrial gas turbine Designed for r

28、eliabilitySimple and robust Single rotor with tilting pad type bearings Cold end drive All welded compressor rotor Annular combustor Bolted 3-stage turbineMaintainable Modular design On-site maintenanceBearing#1(radial+thrust)Engine inletAnnular cc with 30 dual fuel DLE burnersBearing#2(radial)15 st

29、age compressor3 stages variable guide vanesDrive shaft to gear box6600 rpmEngine exhaust diffuser3 stage turbine.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 32Contents Main features,benefits and experience Performance characteristics Package design Core engine de

30、sign Maintenance Reference sitesSGT-800 Industrial gas turbine.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 33SGT-800 Industrial gas turbine Easy on-site maintenance Modular build-up for easy maintenance on site No need for special workshops maintenance Gas turbin

31、e can be removed on rollers through the sliding door Removable burners for short and easy inspection Vertically split compressor casing.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 34Basic Maintenance PlanSGT-800 Industrial gas turbine Maintenance ProgrammeEq.Op.H

32、rs x 1000 OperationMaintenanceLevel DLevel CLevel BLevel A102030405060708090100110120.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 35SGT-800 Service in situRemoval of the turbine module.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Pa

33、ge 3624-hour telephone supportEmergency storeEmergencygas generatorEmergency back-upOperation support 24/7 emergency phone On-line remote troubleshooting Remote Monitoring SystemEmergency resources Service engineers Tools&spare parts Core engine&modules Service depotsGuaranteed mobilization time Per

34、sonnel-24 hours Tools,spares,engine&modules to site or to international freight forwarder within 72 hours.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 37Remote monitoring(STA-RMS)Data collection Decision Support Reporting Risk Mitigation O&M support Solutions/Impr

35、ovements Trouble shootingCustomerClosed LoopServiceExpertsDiagnosticsTeamFLEET INPUTPlant Data:Operational Data.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 38Remote monitoring(STA-RMS)Siemens system provides.our customer with a professional tool for optimisation

36、of operation,i.e.increased reliability and availability built-in OEM knowledge access to real and historic data monitoring of performance monitoring/trending and plotting of vibrations for analysis and diagnostics a powerful tool for the continuous improvement process the possibility of remote softw

37、are upgrades without a site visitResults in a way to optimise operation by storing,analysing and exchanging information.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 39Contents Main features,benefits and experience Performance characteristics Package design Core en

38、gine design Maintenance Reference sitesSGT-800 Industrial gas turbine.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 40Riga SCC-800 x 2DHSGT-800 Industrial gas turbineCombined Cycle applicationRiga,Latvia Combined heat and power plant supplying electricity and distr

39、ict heating for the city of Riga.Owned by Latvenergo,the Latvian national electricity company Turn key delivery from Siemens including two SGT-800s,steam turbine,two supplementary fired HRSG,auxiliaries and balance of plant Handed over to customer on schedule 2005 Nominal power output 140 MW and up

40、to 150 MWth for district heating DLE combustors operating on natural gas.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 41SGT-800 Industrial gas turbineSimple Cycle applicationMMPA SGT-800 x1SCCity of Chaska,Minnesota,USA SGT-800 in peaking application located in Ci

41、ty of Chaska,Minnesota,USA providing power to the Minnesota Municipal Power Agency Remote monitoring by an energy services company located 40 km from Chaska Dual fuel combustors with DLE meets the emission limits without water injection In operation since 2002.E O IP Siemens Industrial Turbomachiner

42、y AB 2011.All rights reserved.SGT-800Page 42SGT-800 Industrial gas turbineCogen applicationGendorf SSC-800 x1CogenGendorf,Germany Extension of the existing combined heat and power plant by providing heat and power for InfraServBayernwerks chemical plant Electrical output 47MW with 37.69%efficiency D

43、ual fuel combustion system with DLE to fulfil the German emission legislation Base load unit in operation since 2002 and with more than 65000 hours of operation InfraServBayernwerk Gendorf Gmbh has a Long Term Service Agreement with Siemens to ensure optimal operation and functionality.E O IP Siemen

44、s Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 43SGT-800 Industrial gas turbineSolution to worldwide customer demands Low emissions for environmental compliance at full and part load Compact layout Simple and robust design for reliable operation Excellent in combined cycle Compe

45、titive life-cycle cost.E O IP Siemens Industrial Turbomachinery AB 2011.All rights reserved.SGT-800Page 44DisclaimerThis document contains forward-looking statements and information that is,statements related to future,not past,events.These statements may be identified either orally or in writing by

46、 words as“expects”,“anticipates”,“intends”,“plans”,“believes”,“seeks”,“estimates”,“will”or words of similar meaning.Such statements are based on our current expectations and certain assumptions,and are,therefore,subject to certain risks and uncertainties.A variety of factors,many of which are beyond

47、 Siemens control,affect its operations,performance,business strategy and results and could cause the actual results,performance or achievements of Siemens worldwide to be materially different from any future results,performance or achievements that may be expressed or implied by such forward-looking

48、 statements.For us,particular uncertainties arise,among others,from changes in general economic and business conditions,changes in currency exchange rates and interest rates,introduction of competing products or technologies by other companies,lack of acceptance of new products or services by custom

49、ers targeted by Siemens worldwide,changes in business strategy and various other factors.More detailed information about certain of these factors is contained in Siemens filings with the SEC,which are available on the Siemens website, and on the SECs website,www.sec.gov.Should one or more of these r

50、isks or uncertainties materialize,or should underlying assumptions prove incorrect,actual results may vary materially from those described in the relevant forward-looking statement as anticipated,believed,estimated,expected,intended,planned or projected.Siemens does not intend or assume any obligati

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 办公、行业 > 各类PPT课件(模板)
版权提示 | 免责声明

1,本文(SGT800-Product-presentat教学讲解课件.ppt)为本站会员(ziliao2023)主动上传,163文库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。
2,用户下载本文档,所消耗的文币(积分)将全额增加到上传者的账号。
3, 若此文所含内容侵犯了您的版权或隐私,请立即通知163文库(发送邮件至3464097650@qq.com或直接QQ联系客服),我们立即给予删除!


侵权处理QQ:3464097650--上传资料QQ:3464097650

【声明】本站为“文档C2C交易模式”,即用户上传的文档直接卖给(下载)用户,本站只是网络空间服务平台,本站所有原创文档下载所得归上传人所有,如您发现上传作品侵犯了您的版权,请立刻联系我们并提供证据,我们将在3个工作日内予以改正。


163文库-Www.163Wenku.Com |网站地图|