1、ConfidentialPortable Computing GroupSafety TestSafety Test 安規測試安規測試ConfidentialPortable Computing GroupTest Item Insulation Resistance Test Insulation Endurance Test Leakage Current Test Inrush Current TestConfidentialPortable Computing GroupInsulation Resistance Test Aim Verify insulation strength
2、of products (驗證產品的絕緣強度)Spec Test point:(A+B)FG Test voltage:DC500V Test time:1minute System condition:System power off Criteria Insulation Resistance:10meg ohmConfidentialPortable Computing Group Step ConfidentialPortable Computing GroupConfidentialPortable Computing GroupInsulation Endurance TestAi
3、m Insulation Strength is tested using far higher than normal voltage to observe whether insulation is damaged or leakage current is too high.(以高於正常使用電壓的條件測試產品之絕緣強度,以觀察絕緣是否崩潰或洩漏電流是否過高,判定產品是否安全)ConfidentialPortable Computing GroupSpec Test point:(A+B)FG Test voltage:AC 1.5KV(130250)AC 1.0KV(Less than1
4、30V)Test time:1 minute System condition:System power offCriteria Leakage Current:10mAConfidentialPortable Computing GroupStepConfidentialPortable Computing GroupConfidentialPortable Computing GroupLeakage CurrentAim Under normal voltage,simulating when body contacts product,the current is checked wh
5、ether to damage the safety of body.(在正常的工作電壓下,模擬人體接觸產品時流經人體之電流量以檢視該電流量是否危害人身安全。)Spec *Test point:A FG,B FG,FGEarth,Palm RestEarth ConfidentialPortable Computing Group *Input Resistance:1.5Kohm *Input capacity:0.15F *Input voltage:Standard voltage+10%Criteria:ConfidentialPortable Computing GroupStepC
6、onfidentialPortable Computing GroupAC 220VN/B之电源插座AC Power SourceConfidentialPortable Computing GroupConfidentialPortable Computing GroupConfidentialPortable Computing GroupConfidentialPortable Computing GroupInrush Current Aim 驗證產品在開關暫態之電流突破是否合乎產品規格Spec Test voltage:100V/230V Test frequency:50HZ/60
7、HZ Trigger point:AC plug in Measure times:5 times for each Condition:System cold ConfidentialPortable Computing GroupMeasure Item:Inrush current:0 to peakLasting time:The time from the start to x1.25 with standard current value其中x的确定为:从波形start到波形稳定时的緃坐标 之差Criteria:Inrush Current:52ALasting Time:500ms ConfidentialPortable Computing Group